Ilmu Telekomunikasi    
   
Daftar Isi
(Sebelumnya) Intelligent lightingInter frame (Berikutnya)

Intelligent Platform Management Interface

The Intelligent Platform Management Interface (IPMI) is a standardized computer system interface used by system administrators for out-of-band management of computer systems and monitoring of their operation.

The development of this interface specification was led by Intel Corporation and is supported by more than two hundred computer systems vendors.[1] Cisco, Dell, Hewlett-Packard, Intel, and NEC Corporation announced IPMI v1.0 on 1998-09-16, v1.5 on 2001-03-01, and v2.0 on 2004-02-14.

Contents

Functionality

IPMI is a message-based, hardware-level interface specification: an IPMI subsystem operates independently of the operating system (OS) (i.e. out-of-band) to allow administrators to manage a system remotely in the absence of an operating system or of the system management software, and thus can be used before an OS has booted (allowing e.g. BIOS settings to be remotely monitored or changed), when the system is powered down, or after OS or system failure, which is the key characteristic of IPMI compared with in-band system management such as by remote login using SSH. Being a standardized interface and protocol allows systems management software based on IPMI to manage multiple disparate servers.

System administrators can use IPMI messaging to monitor platform status (e.g. system temperatures, voltages, fans, power supplies and chassis intrusion); to query inventory information; to review hardware logs of out-of-range conditions; or to perform recovery procedures such as issuing requests from a remote console through the same connections e.g. system power-down and rebooting, or configuring watchdog timers. The standard also defines an alerting mechanism for the system to send a simple network management protocol (SNMP) platform event trap (PET).

The monitored system may be powered off, but must be connected to a power source and the monitoring medium, typically a local area network connection. IPMI can also function after the operating system has started, and exposes management data and structures to the system management software. IPMI prescribes only the structure and format of the interfaces as a standard, while detailed implementations may vary. An implementation of IPMI version 1.5 can communicate via a direct out-of-band local area network (LAN) or serial connection or via a side-band local area network (LAN) connection to a remote client. The side-band LAN connection utilizes the board network interface controller (NIC). This solution is less expensive than a dedicated LAN connection but also has limited bandwidth. Systems compliant with IPMI version 2.0 can also communicate via serial over LAN, whereby serial console output can be remotely viewed over the LAN. Systems implementing IPMI 2.0 typically also include KVM over IP, remote virtual media and out-of-band embedded web server interface functionality, although these are strictly outside of the scope of the IPMI interface standard.

DCMI (Data Center Management Interface) is a similar standard based on IPMI but designed to be more suitable for Data Center management: it uses the interfaces defined in IPMI, but minimizes the number of optional interfaces and includes power capping control, among other differences.

Side-band and out-of-band

As well as using a separate dedicated management LAN connection, IPMI also allows implementation of what is often called a "side-band" management LAN connection. This connection utilizes a System Management Bus (SMBUS) interface between the BMC (Baseboard Management Controller) and the board Network Interface Controller (NIC). This solution has the advantage of reduced costs but also provides limited bandwidth – sufficient for text console redirection but not for video redirection. For example, when a remote computer is down the system administrator can access it through IPMI and utilize a text console. This will be sufficient for a few vital functions, such as checking the event log, accessing the BIOS setup and perform power on, power off or power cycle. However, more advanced functions, such as remote re-installation of an operating system, may require a full out-of-band management approach utilizing a dedicated LAN Connection.[citation needed]

IPMI components

An IPMI sub-system consists of a main controller, called the baseboard management controller (BMC) and other management controllers distributed among different system modules that are referred to as satellite controllers. The satellite controllers within the same chassis connect to the BMC via the system interface called Intelligent Platform Management Bus/Bridge (IPMB) — an enhanced implementation of I²C (Inter-Integrated Circuit). The BMC connects to satellite controllers or another BMC in another chassis via the Intelligent Platform Management Controller (IPMC) bus or bridge. It may be managed with the Remote Management Control Protocol (RMCP), a specialized wire protocol defined by this specification. RMCP+ (a UDP-based protocol with stronger authentication than RMCP) is used for IPMI over LAN.

IPMI architecture diagram shows BMC sideband via SMBUS.
Interfaces to the baseboard management controller

Several vendors develop and market BMC chips. A BMC utilized for embedded applications may have limited memory and require optimized firmware code for implementation of the full IPMI functionality. Highly integrated BMCs can provide complex instructions and provide the complete out-of-band functionality of a service processor. The firmware implementing the IPMI interfaces is provided by various vendors. A field replaceable unit (FRU) holds the inventory, such as vendor ID and manufacturer, of potentially replaceable devices. A sensor data record (SDR) repository provides the properties of the individual sensors present on the board. For example, the board may contain sensors for temperature, fan speed, and voltage.

Baseboard management controller

The baseboard management controller (BMC) is the intelligence in the IPMI architecture. It is a specialized microcontroller embedded on the motherboard of a computer, generally a server. The BMC manages the interface between system management software and platform hardware.

Different types of sensors built into the computer system report to the BMC on parameters such as temperature, cooling fan speeds, power status, operating system (OS) status, etc. The BMC monitors the sensors and can send alerts to a system administrator via the network if any of the parameters do not stay within preset limits, indicating a potential failure of the system. The administrator can also remotely communicate with the BMC to take some corrective action such as resetting or power cycling the system to get a hung OS running again. These abilities save on the total cost of ownership of a system.

Physical interfaces to the BMC include SMBus buses, an RS-232 serial console, address and data lines and an Intelligent Platform Management Bus (IPMB), that enables the BMC to accept IPMI request messages from other management controllers in the system.

A direct serial connection to the BMC is not encrypted as the connection itself is secure. Connection to the BMC over LAN may or may not use encryption depending on the security concerns of the user.

There are rising concerns about the general security regarding BMCs as a closed infrastructure.[citation needed]

See also

  • Out-of-band management (aka Lights out management (LOM))
  • HP Integrated Lights-Out (HP's implementation of IPMI)
  • Dell DRAC (Dell's implementation of IPMI)
  • IBM Remote Supervisor Adapter (IBM's out-of-band management products, including IPMI implementations)
  • MegaRAC (AMI's out of band management product and OEM IPMI firmware used in e.g. ASUS, Tyan, Intel and Supermicro motherboards)
  • Avocent MergePoint Embedded Management Software (OEM IPMI firmware used in e.g. DELL and Gigabyte motherboards)
  • Intel Active Management Technology (iAMT, an Intel out-of-band management product- an alternative to IPMI)
  • DMTF Alert Standard Format (ASF) Another platform management standard.
  • DMTF Desktop and mobile Architecture for System Hardware (DASH) Another platform management standard.
  • Wired for Management (WfM)

References

External links

(Sebelumnya) Intelligent lightingInter frame (Berikutnya)